As the proud owner of a PURIFIED ICE station self-service ice vending machine, you’re on the brink of transforming your space into a refreshing oasis. However, before you start enjoying the cool benefits, it’s essential to master the art of installation. This step-by-step guide will walk you through the process, ensuring a seamless setup that guarantees optimal performance.
1. Selecting the Perfect Installation Site: Choosing the right location is crucial for the machine’s efficiency and longevity. Ensure the site is flat, away from direct sunlight and rain. Avoid corrosive environments and verify that the ground can support a load of over 1000KG. Maintain proper distances from walls, as specified in the guidelines.
2. Installing the Support Feet: After determining the installation position, secure the four adjusting support legs to keep the machine level and stable. This step is vital to prevent any swinging. Utilize the provided nuts and bolts, and secure the machine to the ground using expansion screws.
3. Water and Drainage Setup: For the water inlet, use a 4-point PVC or aluminum-plastic pipe with corresponding joints. The drainage pipe requires a 4-point reticulated rubber hose. Ensure proper installation, and remember that the drainage level must not be higher than the bottom of the machine for smooth operation.
4. Powering Up: Selecting the right power cord is crucial for a safe and efficient setup. For the 180/320/450KG type, use a 220V or 380V, not less than 3×2.5㎡ cable. The 900KG type requires a 5×2.5㎡ cable. Ensure the power supply uses a distribution box with a leakage protector. Proper grounding is essential, and follow the specifications to avoid any mishaps.
5. Power Connection Diagram: Refer to the provided diagrams for power supply connection based on your machine type. It’s imperative to distinguish between positive and negative phases for three-phase power supply to ensure the motor rotates correctly.
6. Important Warnings:
- Use only clean and sanitary water sources within specified pressure ranges.
- Ensure the ambient temperature falls between 5 and 38°C for optimal performance.
- The water inlet pipe connection must be leak-proof under a water pressure of 0.6MPa.
Conclusion: With these comprehensive installation steps, you’re now equipped to set up your PURIFIED ICE station machine like a pro. Follow each guideline meticulously to enjoy a continuous supply of high-quality, refreshing ice. Welcome to a world where convenience meets coolness, and your PURIFIED ICE station machine becomes the centerpiece of your refreshing haven. Stay cool, stay refreshed!